Medical
Nitrocellulose (NC) Membrane

Nitrocellulose membrane, also known as NC membrane, works in the place where the immune reaction occurs, and is the most important lateral flow immunoassays membrane in the test strip. As microporous membrane, NC membrane’s function is immobilizing the target molecule, which will be adsorpted in the test line (T-line) and the control line (C-line), while the conjugate of the sample is guided to flow into the reaction area. Lateral flow test strip consists of 4 parts: sample pad / blood separator, conjugated pad, reaction membrane (NC membrane) and absorption pad. 


Cobetter NC140C and NC95C are perfectly suitable for lateral chromatography diagnostic manufacturers’ requirement. According to different application scenarios, Cobetter provides NC membranes in different capillary and sizes with excellent performance and consistency.


Nitrocellulose membrane 02 cbt.png



Basic Properties

ItemCobetter NC140CCobetter NC95C

sem-01.png

sem-02-01.png

Capillary Speed (s/4cm):13485

Coating Thickness
(without backing) (μm):

157116
Backing Thickness (μm):120131





Advantages

- High porosity, excellent protein binding ability, high sensitivity and rapid detection

- Extraordinary hydrophilicity, instant wetting to ensure consistent lateral flow rate 

- Low background allowing longer exposure time, lowering interference on test results 

- Various options of pore sizes and capillary speed can be selected 

- Evenly thickness, consistent signal test result is easy-to-read 

- Smooth surface with no defect 

- High consistency ensures accurate and reliable test results 

- Length and width be customized



Application

As membrane for lateral flow tests, nitrocellulose membrane is the most important material in immunochromatographic diagnosis technology. Customers could select suitable membrane with different pore sizes according to their requirements on sensitivity, which decide different chromatographic speed. 


Each of Cobetter NC diagnostic membrane has a specific capillary velocity range. NC95C is very suitable for high viscosity samples and can be used for test strips with short response time in contrast, the capillary speed of NC140C is slightly slower and the response time is longer, but the protein binding ability is stronger and the detection sensitivity is higher.

Applications, regents and production conditions are taken into consideration during the development of Cobetter NC95C and NC140C membranes. So, they can provide different options regarding detection speed, specificity and sensitivity for our customers.


Applicable Test Method for Cobetter NC Membrane

Immunochromatography based on lateral flow, such as:
- Colloidal Gold Immunochromatography Assay(GICA)
- Latex Immunochromatography Assay
Fluorescence Immunochromatography Assay



Applications for Test Strip with Cobetter NC membrane

- Covid-19 Test
- Infectious Disease Test
- Myocardial and Inflammatory Test
- Early Pregnancy Test
- Drug Detection
- Food and Pesticide Test


Membrane Formats

- Rolls/ Discs/ Customized



Specifications

FormatSpecificationBackingWidth (mm)Length (m)
RollNC140C-18Yes18100
NC140C-20Yes20100
NC140C-22Yes22100
NC140C-25Yes25100
NC95C-18Yes18100
NC95C-20Yes20100
NC95C-22Yes22100
NC95C-25Yes25100
SheetNC140C-F30025Yes250.3
NC95C-F30025Yes250.3

Other sizes can be customized. Look forward to your inquiry!



Key Words
NC Membrane
Nitrocellulose Membrane
Membrane for Lateral Flow Tests
Nitrocellulose Microporous Membrane
Cellulose Nitrate Membrane
Lateral Flow Membranes Vitro
Diagnostic Membrane
Lateral Flow Nitrocellulose Membrane
Diagnostic Nitrocellulose Membrane Lateral Flow
Immunoassays Membrane Immunoassay Rapid Test Components





For technical data sheet or application inquiry, you are more than welcome to contact our sales representative by sales@cobetterfilter.com or leave a message